MHS SERIES : HORIZONTAL SAND FILTER – PHYSICAL & TECHNICAL DETAILS


  • “Flow Range” is based on a design rate of 15 to 42 m3/hr/m2 – filter rates will vary according to application
  • Nominal backwash duration is 4 minutes – Refer to CGF for possible backwash methods and details.
  • “Filter Media” requirements include a substrate layer providing lateral coverage.
  • FRP vessels are “contacted moulded” as a monolithic structure with reinforced entry & exit ports.
  • Standard Test Pressure is 350kPa – higher test pressures are available.
  • Model specific data sheets/sales outlines are available upon request.
  • Dimensions are not to be used for construction or installation, unless certified for this purpose by CGF
  • Details may be subject to change without notice and are for reference only.